Home Link Exchange Banner Exchange Advertise with Us Site Map
 
 
1
Music Jokes Jokes Msn Corner MSN Corner Funny SMS Girl Section GIrls Section Articles Articals
Picture Galleries Picture Galleries Wallpapers Wallpapers Forum Forum Cancer Awareness Cancer Awareness Mehndi Designs Mehndi Designs Shayari Shayari
Ringtones Ringtones Recipes Recipes Funny Videos Funny VIdeos Online Games Online Games Funny Videos Mobile 3gp Videos Cricket Videos Cricket Videos
2
Main Menu
Islam
Pakistan
Mobile Maza
Wallpapers
Msn Zone
Free Downloads
Flash Fun
Beauty Tips
Healthy Tips
Computer Tips
Cooking
Earning Money Tips
Modeling
Jokes
Fashion Channel
Funny Games
Mobile Tips & Tricks
Online Jobs
XP tips
 
Fun Corner
Funny Name Maker
Funny Video Clips
Flash Fun Pages
Funny Wallpapers
 
Site Tools
Link Exchange
Advertisw with Us
Site Map
Contact Us
Motorola Mobile Tips & Tricks
 
Nokia Tips & Tricks
 

Motorola d460

*#06# for checking the IMEI (International Mobile Equipment Identity)

Activate RBS

(Note: pause means the * key held in until box appears)
To activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 1 [pause] [ok]
You now have to press the [MENU] and scroll to the 'Eng Field Options' function with the keys, and enable it.

De-activate RBS

To de-activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 0 [pause] [ok]
This only works with some versions of software.

What's the use of RBS:

Get Distance From Base Station - Place a call, when it is answered, press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'Time Adv xxx' appears, where xxx is a number. Multiply this number by 550, and the result is the distance from the RBS (Radio Base Station), in meters.

Get Signal Quality - press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'C1' appears. This is the signal quality. If it becomes negative for longer than 5 seconds, a new cell is selected.

Motorola 6200

Activate RBS

(Note: pause means the * key held in until box appears)
To activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 1 [pause] [ok]
You now have to press the [MENU] and scroll to the 'Eng Field Options' function with the keys, and enable it.

De-activate RBS

To de-activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 0 [pause] [ok]
This only works with some versions of software.

These countries has been reported working:

UK (Orange)
AU

What's the use of RBS:

Get Distance From Base Station - Place a call, when it is answered, press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'Time Adv xxx' appears, where xxx is a number. Multiply this number by 550, and the result is the distance from the RBS (Radio Base Station), in meters.

Get Signal Quality - press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'C1' appears. This is the signal quality. If it becomes negative for longer than 5 seconds, a new cell is selected.

Pin Outs

Numbered left to right, keypad up, battery down

1. Audio Ground
2. V+
3. True data (TD) (input)
4. Downlink - Complimentary data (CD) (input)
5. Uplink - Return data (RD) (output)
6. GND
7. Audio Out - on/off
8. Audio In
9. Manual Test - ???
10. Battery Feedback
11. Antenna connector

Motorola 7500

Activate RBS

(Note: pause means the * key held in until box appears)
To activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 1 [pause] [ok]
You now have to press the [MENU] and scroll to the 'Eng Field Options' function with the keys, and enable it.

De-activate RBS

To de-activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 0 [pause] [ok]
This only works with some versions of software.

These countries has been reported working:

IT (model: F16 HW: 5.2 SW: 2.1)

What's the use of RBS:

Get Distance From Base Station - Place a call, when it is answered, press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'Time Adv xxx' appears, where xxx is a number. Multiply this number by 550, and the result is the distance from the RBS (Radio Base Station), in meters.

Get Signal Quality - press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'C1' appears. This is the signal quality. If it becomes negative for longer than 5 seconds, a new cell is selected.

Pin Outs

Numbered right to left, keypad up, battery down looking

1. Gnd
2. Pos
3. True data (TD) (input)
4. Complimentary data (CD) (input)
5. Return data (RD) (output)
6. Audio gnd
7. Audio out
8. Audio in

Motorola 8200

Activate RBS

(Note: pause means the * key held in until box appears)
To activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 1 [pause] [ok]
You now have to press the [MENU] and scroll to the 'Eng Field Options' function with the keys, and enable it.

De-activate RBS

To de-activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 0 [pause] [ok]
This only works with some versions of software.

These countries has been reported working:

ES, AU, NL, BE

What's the use of RBS:

Get Distance From Base Station - Place a call, when it is answered, press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'Time Adv xxx' appears, where xxx is a number. Multiply this number by 550, and the result is the distance from the RBS (Radio Base Station), in meters.

Get Signal Quality - press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'C1' appears. This is the signal quality. If it becomes negative for longer than 5 seconds, a new cell is selected.

Pin Outs

Numbered right to left, keypad up, battery down looking

1. Audio Ground
2. V+
3. True data (TD) (input)
4. Downlink - Complimentary data (CD) (input)
5. Uplink - Return data (RD) (output)
6. GND
7. Audio Out - on/off
8. Audio In
9. Manual Test - ???
10. Battery Feedback
11. Antenna connector

Motorola 8400

Activate RBS

(Note: pause means the * key held in until box appears)
To activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 1 [pause] [ok]
You now have to press the [MENU] and scroll to the 'Eng Field Options' function with the keys, and enable it.

De-activate RBS

To de-activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 0 [pause] [ok]
This only works with some versions of software.

These countries has been reported working:

IT, NL

What's the use of RBS:

Get Distance From Base Station - Place a call, when it is answered, press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'Time Adv xxx' appears, where xxx is a number. Multiply this number by 550, and the result is the distance from the RBS (Radio Base Station), in meters.

Get Signal Quality - press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'C1' appears. This is the signal quality. If it becomes negative for longer than 5 seconds, a new cell is selected.

Pin Outs

Numbered left to right, keypad up, battery down

1. Audio Ground
2. V+
3. True data (TD) (input)
4. Downlink - Complimentary data (CD) (input)
5. Uplink - Return data (RD) (output)
6. GND
7. Audio Out - on/off
8. Audio In
9. Manual Test - ???
10. Battery Feedback
11. Antenna connector

Motorola 8700

#06# for checking the IMEI (International Mobile Equipment Identity)

Activate RBS

(Note: pause means the * key held in until box appears)
To activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 1 [pause] [ok]
You now have to press the [MENU] and scroll to the 'Eng Field Options' function with the keys, and enable it.

De-activate RBS

To de-activate RBS type: [pause] [pause] [pause] 1 1 3 [pause] 0 [pause] [ok]
This only works with some versions of software.

These countries has been reported working:

AU, IT, SG, DE, ES, ZA

What's the use of RBS:

Get Distance From Base Station - Place a call, when it is answered, press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'Time Adv xxx' appears, where xxx is a number. Multiply this number by 550, and the result is the distance from the RBS (Radio Base Station), in meters.

Get Signal Quality - press [MENU] until 'Eng Field Option' is displayed, press [OK], select 'Active Cell', press [OK], press [MENU] until 'C1' appears. This is the signal quality. If it becomes negative for longer than 5 seconds, a new cell is selected.

Motorola V3688

*#06# for checking the IMEI (International Mobile Equipment Identity)

Enhanced Full Rate Codec (EFR):

To Enable EFR press [][][] 119 [] 1 [] OK.
To Disable EFR press [][][] 119 [] 0 [] OK

NOTE: Nothing appears on Screen.

Other Phones from Motorola (CD 160, CD 520, 920, 930)

Motorola CD 160

Press menu and type one of these numbers and press OK:

11 = Status Review
13 = Available Networks
14 = Preferred Networks
22 = Select Keypad Tones
25 = Require SIM Card PIN
26 = Language Selection
32 = Repetitive Timer
33 = Single Alert Timer
34 = Set IN-Call Display
35 = Show Call Timers
36 = Show Call Charges
37 = Call Charge Settings
38 = Reset All Timers
43 = Reset All Timers
45 = Show Last Call
46 = Total For All Calls
47 = Lifetime Timer
51 = Change Unlock Code
52 = Master Reset
53 = Master Clear (Warning!! May result in deleting the Message Editor!!!)
54 = New Security Code
55 = Automatic Lock
63 = Battery Saving Mode

Free call tip
1 Enter the phone number
2 Enter OK
3 Type *#06#
4 Press Button C
5 And finally press the button for power off.

You should now be able to talk without being billed.

Motorola CD 520

Free call tip
1 Enter the phone number
2 Enter OK
3 Type *#06#
4 Press Button C
5 And finally press the button for power off.

You should now be able to talk without being billed.

Motorola 920/930

The 54# Tip:
Type 1#, 2#........54# on the keypad (when you're not in the menu) to get the phone number used for with this key when speed dialing.

Keyboard lock
if you push * and # on the same time your keyboard locked. When you press it again, you unlock your keyboard.

Supplementary Menu
If your Motorola CD920 or 930 has the engineering software, you can get an engineering mode by typing : ***113*1*, but you have to maintain each * during 3 sec to get a square. So 3 squares, 113, 1 square, 1, 1 square, CALL.
If the software is present you have one supplementary menu. To remove it typ ***113*0* like above.

To put the counter to 0 even global counter, just do a reset factory in the Config menu.

 
Note:
Nokia Tips & Tricks. Here you will find many hidden tricks which you can perform on your phones to get more from your phones. Unlike other websites Mobiles Eden provides wide range of codes for your mobile phones to make them work more.
 
<< Go To Back
If you find any link wrong/broken, please report us.
 
 
 
_________________________________________________________________________________________________
  Best Viewed In Internet Explorer 5+ & 800x600 Resolution
www.MastiXone.com
© Copyright 2008-2009 . All rights reserved